<u id="fkggp"><noscript id="fkggp"><pre id="fkggp"></pre></noscript></u>

    <nav id="fkggp"><strong id="fkggp"></strong></nav>

    精品自拍视频,国产精品内射久久久久欢欢,羞羞成人一区,亚洲AV成人无码久久精品四虎,亚洲国产粗大,草莓AV,国产大神精品在线播放,www.欧美精品
    Products Current Location:Home > Products > Details
    Agilent 86116C
    • Agilent 86116C
    Agilent 86116C
     

    Product Model:

             Agilent 86116C
     

    Product Manufacturer:

             Keysight/Agilent
     

    Product Attributes Classification:

             Optical Communication
     

    Product Attributes:

             Wide-Bandwidth Oscillscope
    Product Description

    Agilent 86116C-040 65 GHzOptical/80 GHz Electrical Module

    主要特性與技術(shù)指標(biāo)

    86116C-040 Optimized for high-speed telecom signals

    40G SONET/SDH and faster signals

    70 GHz characteristic optical bandwidth displays up to 107 Gb/s NRZ

    Reference receiver for 39.8 and 43.0 Gb/s NRZ

    93 GHz characteristic electrical bandwidth

    55, 30 GHz settings for best sensitivity (0.6, 0.5 mVRMS characteristic)

    描述

    Cutting edge component and subsystem designs require accurate characterization of very high-speed signals. When viewing waveforms in the 10 to 100 Gb/s range, three requirements are critical in an oscilloscope: a well designed frequency response, a wide bandwidth, and extremely low internal jitter. The 86116C optical and electrical modules represent some of the fastest solutions available for measuring high-speed communication signals. Characteristically with 70 GHz optical and 93 GHz electrical bandwidth, the 86116C when paired with the 86107A precision timebase module becomes the ideal solution for ultra high-speed waveform analysis. Designers will see the real performance of their devices and not aberrations created by the test equipment.

    The unfiltered bandwidth settings provide the best pulse fidelity mode for measurement and display of very high-speed waveforms and provides a fast full-width, half-max (FWHM) of less than 7.4 ps (86116C-040). User selectable bandwidth settings can reduce noise when observing small signals. The electrical channel features over 93 GHz bandwidth. This yields a 3.9 ps system risetime. Just as important as bandwidth, the channel has a well controlled frequency response to minimize waveform distortion. User selectable bandwidth settings can be used for reduced instrumentation noise.

    Previous:Agilent 86116B
    Next:Agilent 86116C
    About Us
    Company Profile
    Jobs
    Operating Project
    Company Culture
    Products
    Products
    News
    Industry News
    Company News
    Feedback
    Feedback
    Contact Us
    Contact Us